My soakaway failed the percolation test – what now?

23 November 2026 · Blog · Drainage

You’re building an extension or a new home, Building Control or the planning officer wants rainwater to go to a soakaway, and the infiltration test has come back poor: the water barely drained away. It’s very common, especially on the clay found across much of London, Essex and the Weald. The good news is that it’s rarely a dead end.

First, check the test itself
A soakaway is designed from a BRE 365 infiltration test in a trial pit. Before giving up on infiltration, it’s worth asking:
• Was the pit dug at the depth and location where the soakaway would actually go?
• Was it filled and allowed to drain the required number of times, or abandoned early?
• Could a different part of the site, or a slightly different depth, reach better-draining ground such as sand or gravel?
Sometimes a second test in the right place gives a usable result.

Why a soakaway can’t just be made bigger
On very slow-draining clay, a soakaway would need to be impractically large, and water standing in it for days can soften the ground near foundations. That’s why Building Regulations allow you to move on to the next option when infiltration isn’t practical.

The alternatives we design
• Attenuation: crates or a tank that store the rainwater and release it slowly, through a flow control, to a sewer or watercourse. This is the most common solution on clay.
• Permeable paving and rain gardens: these slow and store water across the site and can reduce the size of any tank.
• Water butts and rainwater harvesting: useful for cutting the volume, though rarely enough on their own.
• A watercourse connection: if there’s a ditch or stream nearby, with consent where needed.
• A sewer connection: usually to a surface water sewer, with the water company’s agreement and often at a limited rate.

Building Regulations Part H sets this order: infiltration first, then a watercourse, then a sewer. Your drawings need to show Building Control why each step was or wasn’t possible, and our design report sets that out for you.

Common questions

Do I need a new test for an attenuation design?
Not usually. The failed test is the evidence that infiltration isn’t practical.

Can I connect to the foul sewer?
Only as a last resort, and only with the water company’s agreement. Most won’t accept new surface water into a foul sewer where there’s an alternative.

Who carries out the testing?
We don’t carry out the testing ourselves, but we can recommend a specialist contractor we always use, then design the soakaway or alternative from their results.

Soakaway and drainage design →